Maker |
Specifications |
Brooks Instrument |
810 Magnetic Level Gauge |
810R-1”-C14-M1/2-S1x3-Z24/l-1500 |
Brooks Instrument Vietnam |
Documents (Optional) |
D0-3.1 Material Certificate |
Brooks Instrument Vietnam |
D12-GA drawing |
Brooks Instrument Vietnam |
D13-Conformity/Pressure Test/2.2 Material Cert |
Brooks Instrument Vietnam |
Cert of origin by chamber of commerce |
Brooks instruments Vietnam |
BM Series Oval Gear Meter |
BM50AASF4R1CKAA |
Estimated weight = 15-24 kg package included |
Meter Size BM50A 2 inch |
Body Material A Aluminium |
Rotor/Gear Material S 316 SS Rotor Gear |
Display F Standard LCD Display in Aluminium Housing |
Connection Type 4 ANSI 150lbs RF Flange |
Output / Electronic R Reed Switct |
Viscosity 1 Standard < 1000 cP |
Temperature Class C Standard 316 SS Rotors, 120 degC |
Seals K Teflon |
Options A None |
Documentaiton A None |
Brooks Vietnam |
Brooks Sho-Rate 1355E Series |
Code: 1355EXXXCFX1A |
(Sho-RateTM "150" Model 1355E |
Code: 1355EB2BCFQ1A) |
Brooks instrument Vietnam |
SLA5850 Thermal Mass Flow Controller |
SLA5850SB1AB1B2A1 |
Brooks instrument Vietnam |
9660 High Temperature Mass Flow Meter |
9660CXF-0004 500C-4RHOVAMMUXXXXCX10EXX |
Brooks instrument Vietnam |
SLA5850 Thermal Mass Flow Controller |
SLA5850SB1AB1B2A1 |
Brooks instrument Vietnam |
9660 High Temperature Mass Flow Meter |
9660CXF-0004 010C-4RHOVAMMUXXXXCX10EXX |
Brooks instrument Vietnam |
SLA5850 Thermal Mass Flow Controller |
SLA5850SB1EE1B2A1 |
Digital I/O. Communications S Smart Emulation (Analog and/or RS485) |
Mechanical Connections B1 1/4” Tube Compression Fittings W/Filter |
O-ring Material E EPDM for sensor o-ring, Teflon for the rest |
Valve Seat Material E EPDM |
Valve Type 1 Normally Closed |
Analog I/O B 0-5 Vdc |
Power Supply 2 +24 Vdc |
Output Enhancement A Standard Setting / Response Time |
|
8-14kg package included |
|
Note: We cannot quote with 220VAC power supply. |
BUT We can only do +/-15 V or +24 V type. |
Brooks instrument Vietnam |
Model Code: 2510A2A17SVVT |
Revision A Rev A |
Tube Code 2A17 4-50 LPM air |
Fittings S Stainless Steel |
Valve V Standard Inlet Valve |
Seals VT Viton |
Meter Specifications |
Meter Range : 4– 50 LPM, Air @ 14.7 psia & 70 DegF |
Max Pressure : 100 psi-g |
Max Temperature : 65 °C |
Accuracy : 5% FS |
Fitting : 1/8” NPT-F , inlet back, outlet back |
Brooks instrument Vietnam |
Model Code: 2510A2A18SVVT |
Revision A Rev A |
Tube Code 2A18 10-100 LPM air |
Fittings S Stainless Steel |
Valve V Standard Inlet Valve |
Seals VT Viton |
Meter Specifications |
Meter Range : 10– 100 LPM, Air @ 14.7 psia & 70 DegF |
Max Pressure : 100 psi-g |
Max Temperature : 65 °C |
Accuracy : 5% FS |
Fitting : 1/8” NPT-F , inlet back, outlet back |
Brooks Vietnam |
Brooks Sho-Rate 1355E Series |
Code: 1355EXXXCFX1A |
(Sho-RateTM "150" Model 1355E |
Code: 1355EB2BCFQ1A) |
BrooksInstrument Vietnam |
5850TR Mass Flow Controller |
5850TRGA2C102AA |
Brooks Vietnam |
GF40 Thermal Mass Flow Controller |
O2 200 sccm |
GF040-C-XX-C-0015 200C-T2-A-V-S5-XXXX-A-X-70F |
Brooks Vietnam |
GF40 Thermal Mass Flow Controller |
O2 2 slpm |
GF040-C-XX-C-0015 002L-T2-A-V-S5-XXXX-A-X-70F |
Brooks Vietnam |
GF40 Thermal Mass Flow Controller |
He 2 slpm |
GF040-C-XX-C-0001 002L-T2-A-V-S5-XXXX-A-X-70F |
Brooks Vietnam |
GF40 Thermal Mass Flow Controller |
C2F6 20 sccm |
GF040-C-XX-C-0118 020C-T2-A-V-S5-XXXX-A-X-70F |
Brooks Vietnam |
GF80 Thermal Mass Flow Controller |
Cl2 200 sccm |
GF080-C-XX-C-0019 200C-VX-A-M-S5-XXXX-A-X-70F |
Brooks Vietnam |
BM Series Oval Gear Meter |
Model: BM01ASSPA2BVA |
(Model: BM01BRSPA2BVA) |
Brooks Vietnam |
BM Series Oval Gear Meter |
Model: BM01BRRPA2BKC |
BM01B: 1/4 inch |
Body / Rotor Material RR: PPS Body & Rotor |
Pulser / Display P: Pulse |
Construction A: Standard Construction |
Process connection 2: 1/4” NPT-F |
Switch Type B: Reed Switch and Hall Effe |
O-rings / Seals K: Teflon |
Options C: Hastelloy C Shafts |
(Model: BM01BRSPA2BVA) |
Brooks Vietnam |
BM Series Oval Gear Meter |
Model: BM40ASSN4N1CKAA |
BM40A: 1 ½ inch |
Body / Rotor Material SS: 316 SS |
Pulser / Display N: Mechanical Register- Liters |
Process connection 4: Flange ANSI 150lbs RF |
Switch Type N: None-Mechanical Register |
Viscosity 1: Standard < 1000 cP |
Temperature Class C: Standard 316 SS rotors, 120 degC |
Seals K: Teflon |
Options AA: None |
(Model: BM40ASSN4N1CVAA) |
Brooks Vietnam |
Special note: |
BM01 flow range is 2-100 L/hr. This is lowest. |
Also the model code you selected is no longer valid. For PPS body, we now only supply in PPS rotor and with Hastelloy C Shaft. |
Do note for BM40 with mechanical register, it only shows totalize flow. It does not show flow rate. |
Brooks Instruments Vietnam |
Brooks 3809 Armored Flow meter |
3809EZXXXX |
Note: This is special model due to JIS 10k flange hence model code is temporary showing "XXXX". |
(Flow unit: m3/min |
Flow rate: 12-14 m3/min |
Operating pressure: 7 bar |
Size: 3’’ |
Connection: JIS 10K) |
Brooks Instrument Vietnam |
SLA5853 Thermal Mass Flow Controller |
SLA5853S2JAB2C2A1 |
SLA5853S: Flow Meter, Body 3 |
Digital I/O. Communications: S Smart Emulation (Analog and/or RS485) |
Mechanical Connections: 2J 1-1/2” NPT-F |
O-ring Material A: Viton |
Valve Seat Material B: Viton |
Valve Type 2: Normally Closed (Press Diff > 2 bar) |
Analog I/O C: 4-20 mA |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response Time |
Certification 1: Standard Location (Safe Area) |
Customer Process |
Fluid : Air |
Normal Upstream Pressure : 4 bar-g |
Normal Downstream Pressure : 1 bar-g |
Meter Specifications |
Meter Flow (Full Scale) : 300 Ln/min |
Reference Temp : 0 degC |
Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Rating : 70 bar-g |
Max Temperature : 65 °C |
(Model: SLA5853S/BF 2J A2 B B3 C A1 B1) |
Brooks Instrument Vietnam |
Recalibration Model 5853S/BE2BA3BB2BA1B1 |
For Flow rate between 100-200 slpm N2 Equivalent |
Action : Only recalibration. |
Extra charges if repair required. |
Brooks Instrument Vietnam |
Recalibration Model 5851S/BD2BA1BB2BA1B1 |
Action : Only recalibration. |
Extra charges if repair required |
Brooks Vietnam |
SLA5853 Thermal Mass Flow Controller |
Model: SLA5853SZXXXX |
Flow Meter, Body 3 |
Digital I/O. Communications Smart Emulation (Analog and/or RS485) |
Mechanical Connections 10mm Tube Compression |
O-ring Material Viton |
Valve Seat Material Viton |
Valve Type Normally Closed (Press Diff > 2 bar) |
Analog I/O 0-5 VDC |
Power Supply +24 Vdc |
Output Enhancement Standard Setting / Response Time |
Certification Standard Location (Safe Area) |
Customer Process |
Fluid : Air |
Normal Upstream Pressure : 7 bar-a |
Normal Downstream Pressure : 1-5 bar-g |
Meter Specifications |
Meter Flow (Full Scale) : 400 ln/min |
Reference Temp : 0 degC |
Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Rating : 70 bar-g |
Max Temperature : 65 °C |
Note: Spec reference to T88253/009. |
(Mass flow contronllers and metters |
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS |
SN/Year: T88253/009 2008 |
Modelnumber: 5853SBZ1039 |
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA |
OP - Press: pa = 7 Bar |
Range/ fluid: 0 - 400 ln/min Air |
DN 10 |
Limit PS 70 barg@TS: 21 độ C PT 105 |
barg@TS: 21 độ C) |
Brooks Instrument Vietnam |
Brooks SLA5850 Thermal Mass Flow Controller |
Model Code : SLA5850SB1DD1B2A1 |
SLA5850S Flow Controller, Body 0 |
Digital I/O. Communications S Smart Emulation (Analog and/or RS485) |
Mechanical Connections B1 1/4” Tube Compression w/Filter |
O-ring Material D Kalrez |
Valve Seat Material D Kalrez |
Valve Type 1 Normally Closed |
Analog I/O B 0-5 VDC |
Power Supply 2 +24 Vdc |
Output Enhancement A Standard Setting / Response Time |
Certification 1 Standard Location (Safe Area) |
(MFC 1: 5850S/BC1GA0AAACA1B1 |
Flowrate (30 ml – 3000ml/min) for wet gas(10% wt SO2 +N2 balance). |
Ope. Pressure max: ? (avoid SO2 condensate to liquid) if condition at Temp: 35°C and the flow: wet gas(10% wt SO2 +N2 balance) |
Output signal: 0..5 Vdc with RS232 interface |
Setpoint signal: 0…5 Vdc or 0..100% RS232 |
Connections: 1/4” OD Compression type (male) |
Seals: Kalrez 6375) |
Brooks Vietnam |
SLA5860 Thermal Mass Flow Meter |
Model Code : SLA5860SB1DA0B2A1 |
SLA5860S Flow Meter, Body 0 |
Digital I/O. Communications S Smart Emulation (Analog and/or RS485) |
Mechanical Connections B1 1/4” Tube Compression w/Filter |
O-ring Material D Kalrez |
Valve Seat Material A None |
Valve Type 0 None |
Analog I/O B 0-5 VDC |
Power Supply 2 +24 Vdc |
Output Enhancement A Standard Setting / Response Time |
Certification 1 Standard Location (Safe Area) |
Customer Process |
Fluid: 10% SO2, 5% Water vapor, 85% N2 (percentage in mass) |
Normal Upstream Pressure: 60-150 psig |
Normal Downstream Pressure: 0-110 psig |
Operating temperature : 65 degC |
Meter Specifications |
Meter Flow (Full Scale): 3000 mlst/min |
Reference Temp: 70 degF |
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Rating: 100 bar-g |
Max Temperature: 65 °C |
NOTE: Operating temp cannot exceed 65 degC |
(MFM 1: 5860S/BC1GA0AACA1B1 |
Request: Need to measure correctly (30 ml – 3000ml/min) for wet gas (10% wt SO2 + 5% steam +N2 balance). |
Flow range: 0…3 ln/min for wet gas(10% wt SO2 + 5% steam +N2 balance) |
Inlet pressure: max. 150 psig @ 70°C |
max. 60 psig @ 35°C |
Outlet pressure: 0…110 psig @ 70°C |
0 psig @ 35°C |
Temperature: 35°C…70°C |
Output signal: 0..5 Vdc with RS232 interface |
Setpoint signal: 0…5 Vdc or 0..100% RS232 |
Connections: 1/4” OD Compression type (male) |
Seals: Kalrez 6375) |
Brooks Instrument Vietnam |
Brooks SLA5860 Thermal Mass Flow Meter |
Model Code : SLA5860SB1DA0B2A1 |
SLA5860S Flow Meter, Body 0 |
Digital I/O. Communications S Smart Emulation (Analog and/or RS485) |
Mechanical Connections B1 1/4” Tube Compression w/Filter |
O-ring Material D Kalrez |
Valve Seat Material A None |
Valve Type 0 None |
Analog I/O B 0-5 VDC |
Power Supply 2 +24 Vdc |
Output Enhancement A Standard Setting / Response Time |
Certification 1 Standard Location (Safe Area) |
Customer Process |
Fluid : 10% CH4O (methanol), 10% Water vapor, 30% CO2, 50% H2 (percentage in mass) |
Normal Upstream Pressure : 1.5-10 bar-g |
Operating temperature : 65 degC |
Meter Specifications |
Meter Flow (Full Scale) : 1000 mlst/min |
Reference Temp : 70 degF |
Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Rating : 100 bar-g |
Max Temperature : 65 °C |
NOTE: 1) Operating temp cannot exceed 65 degC. |
2) Metal seals not available. |
(MFM 2: 5860S/BC1GA0AACA1B1 |
Flow: 20…1000 ml/min for wet gas (10% wt MeOH vapour +10% steam +30%CO2 50%H2). |
Inlet pressure:. 1.5 barg….10 barg |
Temperature: 35°C…80°C |
Output signal: 0..5 Vdc with RS232 interface |
Setpoint signal: 0…5 Vdc or 0..100% RS232 |
Connections: 1/4” OD Compression type (male) |
Seals: Metal) |
Brooks Vietnam |
SLA5853 Thermal Mass Flow Controller |
Model: SLA5853SZXXXX |
Flow Meter, Body 3 |
Digital I/O. Communications Smart Emulation (Analog and/or RS485) |
Mechanical Connections 10mm Tube Compression |
O-ring Material Viton |
Valve Seat Material Viton |
Valve Type Normally Closed (Press Diff > 2 bar) |
Analog I/O 0-5 VDC |
Power Supply +24 Vdc |
Output Enhancement Standard Setting / Response Time |
Certification Standard Location (Safe Area) |
Customer Process |
Fluid : Air |
Normal Upstream Pressure : 7 bar-a |
Normal Downstream Pressure : 1-5 bar-g |
Meter Specifications |
Meter Flow (Full Scale) : 400 ln/min |
Reference Temp : 0 degC |
Accuracy : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Rating : 70 bar-g |
Max Temperature : 65 °C |
Note: Spec reference to T88253/009. |
(Mass flow contronllers and metters |
BROOKS INSTRUMENT 6718WX - THE NETHERLANDS |
SN/Year: T88253/009 2008 |
Modelnumber: 5853SBZ1039 |
I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA |
OP - Press: pa = 7 Bar |
Range/ fluid: 0 - 400 ln/min Air |
DN 10 |
Limit PS 70 barg@TS: 21 độ C PT 105 |
barg@TS: 21 độ C) |
Brooks Instrument Vietnam |
Brooks Model 2500 Series Flowmeters |
Code: 2530A4A68SNVT |
2530 Acrylic Flowmeter |
Revision A: Revision A |
Tube Tube 4A68: 2-20 SCFM Air |
Fittings S: Stainless Steel |
Valve N: No Valve |
Seals VT: Viton |
Brooks Vietnam |
Brooks Oval Flowmeters |
Replaced by: BM04 |
Code: BM04ASSF2H1CKAA |
(Brooks Oval Flowmeters, BM Oval Series, Models BM04 Through BM50 ® |
Code: BM04ASSN2N1ARAA) |
Brooks Vietnam |
SLAMF63 Thermal Mass Flow Meter |
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F |
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) |
Mechanical Connections 3A: DIN DN15 PN40 |
O-ring Material B: Buna |
Valve Seat Material A: None (Meter) |
Valve Type 0: None |
Analog I/O G: 4-20mA I/O (PG11 Cable Gland) |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response Time |
Certification 1: Standard Location (Safe Area) |
Valve Orifice Size: A No Orifice |
Mass Flow Restrictor Type 5: LFE |
Flow Restrictor Size D: Size D |
Calibration conditions 1: Single S-series calibration |
OEM Code A: Standard Brooks Label |
Software Revision A: Revision A |
Mounting Attitute 1: Horizontal base down |
Baudrate F: 19200 |
Customer Process: |
Fluid: CO2 |
Normal Upstream Pressure: 18 bar-g |
Meter Specifications: |
Meter Flow (Full Scale): 40 kg/hr |
Reference Temp : 21.1 degC |
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Ratin: 70 bar-g |
Max Temperature: 65 °C |
Ingress Protection: IP66 |
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 |
Note: IP 66 tot hon IP65 |
(SLA5863S3ABA0C2A1A5D1AA |
IP65) |
Brooks Instrument Vietnam |
Model Code: SLA5853S2CAB2B2A1 |
SLA5853 Mass Flow Controller |
Digital I/O, Communication S: Smart Emulation (analog or RS-485) |
Mechanical Connection 2C: 3/8” Compression |
O-ring material A: Viton |
Valve Seat material B: Viton |
Valve Type 2: Normally Close |
Analog I/O B: 0-5 Volt |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response time |
Certification 1: Standard Location |
* Customer Process Data: |
Fluid: Air |
Upstream Pressure: 5-10 kg/cm2-g |
Downstream Pressure: Customer to advice |
* Meter Specifications: |
Meter Range (Full Scale): 500 slpm |
Ref Temperature: 70 degF |
Accuracy: +/- 1% Rate |
Max Pressure Rating: 100 bar g |
Max Temperature: 65 °C |
NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need. |
(Brooks Instrument mass flow controller for nitrogen and air. |
- Flow rate: 0 - 500 lit/minute |
- Compress air about 5 - 10 kg/cm2 |
- I/O digital signal can controlled by computer. |
- Material for flow meter is metal) |
Brooks Vietnam |
SLAMF63 Thermal Mass Flow Meter |
Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F |
Digital I/O. Communications S: Smart Emulation (Analog and/or RS485) |
Mechanical Connections 3A: DIN DN15 PN40 |
O-ring Material B: Buna |
Valve Seat Material A: None (Meter) |
Valve Type 0: None |
Analog I/O G: 4-20mA I/O (PG11 Cable Gland) |
Power Supply 2: +24 Vdc |
Output Enhancement A: Standard Setting / Response Time |
Certification 1: Standard Location (Safe Area) |
Valve Orifice Size: A No Orifice |
Mass Flow Restrictor Type 5: LFE |
Flow Restrictor Size D: Size D |
Calibration conditions 1: Single S-series calibration |
OEM Code A: Standard Brooks Label |
Software Revision A: Revision A |
Mounting Attitute 1: Horizontal base down |
Baudrate F: 19200 |
Customer Process: |
Fluid: CO2 |
Normal Upstream Pressure: 18 bar-g |
Meter Specifications: |
Meter Flow (Full Scale): 40 kg/hr |
Reference Temp : 21.1 degC |
Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS) |
Max Pressure Ratin: 70 bar-g |
Max Temperature: 65 °C |
Ingress Protection: IP66 |
SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66 |
Note: IP 66 tot hon IP65 |
(SLA5863S3ABA0C2A1A5D1AA |
IP65) |
Brooks Vietnam |
0254 Read Out & Control |
Code: 0254AA2B23A |
Type Housing: Panel Mount Kit |
Power Cord For Power Supply: European Power Cord For 220 VAC |
Power Supply Output Voltage: + 24 VDC |
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set |
Options: RS-232 cable, 3 meter, 9 pin Female “D” |
OEM Code: Standard Brooks Labelling |
Brooks Vietnam |
0254 Read Out & Control |
Code: 0254AA2B23A |
Type Housing: Panel Mount Kit |
Power Cord For Power Supply: European Power Cord For 220 VAC |
Power Supply Output Voltage: + 24 VDC |
Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set |
Options: RS-232 cable, 3 meter, 9 pin Female “D” |
OEM Code: Standard Brooks Labelling |
Brooks Instrument Vietnam |
Brooks SLA5863 Thermal Mass Flow Meter |
Model: SLA5863S3ABA0C2A1A5D1AA |
(Model: SLA5863S3A0C2A1A5D1AA |
SN : F13319-001 |
Gas : CO2 |
Flow rate : 0-40kg/h) |
Brooks Instrument Vietnam |
Brooks SLA5863 Thermal Mass Flow Meter |
Model: SLA5863S3ABA0C2A1A5D1AA |
(Model: SLA5863S3A0C2A1A5D1AA |
SN : F13319-001 |
Gas : CO2 |
Flow rate : 0-40kg/h) |
Brooks Instrument Vietnam |
Replaced by: 1250A-D6041 |
Brooks Instrument Flowmeter |
1250 Glass Tube Flow meter |
1250A: Glass Tube Flow Meter With Horizontal Connections |
Tube model: D6041 Glass float |
Fluid Type: Air |
Unit of measurement: CCM |
End Block Material: Stainless Steel |
Valve Designation: Needle Valve at inlet |
O-ring material: Viton |
Fitting: 1/4" NPT-F |
Note: 1510 model is discontinued. Replacement model is 1250. But flow range is not exactly same. I quoted 20-900 ccm Air. Next higher is 50-1200 ccm |
(Model: 1510 with meet the below specifications |
Pressure: 300psig up to 250oF max |
Material : Glass 316SS |
Connections: 1/4"NPT |
Type of Fluid: Gas. |
Flow range: 100-1000ccm |
Line valve inlet) |
Brooks Vietnam |
3809 Armored Flowmeter |
3809/E12D1BEAEAA |
Note: |
· We are assuming it is water for now. |
Do find out the liquid density and viscosity and the flow range required. |
· This model we quoted comes with 4-20mA output transmitter. |
· We follow the code your sales engineer provided. |
· If signal output is not required, please confirm then price is much lower. |
(Model: 3809E12D1) |
Brooks Instrument Vietnam |
5850E Mass Flow Controller |
Brooks Instrument |
Model: 5850EC1BF3PB2A |
S/N: 8611HCO23461/1. |