Mass flow meters Brooks Instruments

hai@tmpvietnam.com

0912 411 068

Mass flow meters Brooks Instruments
Ngày đăng: 14/11/2024 10:40 AM
    Maker Specifications
    Brooks Instrument  810 Magnetic Level Gauge
    810R-1”-C14-M1/2-S1x3-Z24/l-1500
    Brooks Instrument Vietnam Documents (Optional)
    D0-3.1 Material Certificate
    Brooks Instrument Vietnam D12-GA drawing
    Brooks Instrument Vietnam D13-Conformity/Pressure Test/2.2 Material Cert 
    Brooks Instrument Vietnam Cert of origin by chamber of commerce 
    Brooks instruments  Vietnam BM Series Oval Gear Meter
    BM50AASF4R1CKAA
    Estimated weight = 15-24 kg package included
    Meter Size BM50A 2 inch
    Body Material A Aluminium
    Rotor/Gear Material S 316 SS Rotor Gear
    Display F Standard LCD Display in Aluminium Housing
    Connection Type 4 ANSI 150lbs RF Flange
    Output / Electronic R Reed Switct
    Viscosity 1 Standard < 1000 cP
    Temperature Class C Standard 316 SS Rotors, 120 degC
    Seals K Teflon
    Options A None
    Documentaiton A None
    Brooks Vietnam Brooks Sho-Rate 1355E Series
    Code: 1355EXXXCFX1A 
    (Sho-RateTM "150" Model 1355E
    Code: 1355EB2BCFQ1A)
    Brooks instrument Vietnam SLA5850 Thermal Mass Flow Controller
    SLA5850SB1AB1B2A1
    Brooks instrument Vietnam 9660 High Temperature Mass Flow Meter
    9660CXF-0004 500C-4RHOVAMMUXXXXCX10EXX
    Brooks instrument Vietnam SLA5850 Thermal Mass Flow Controller
    SLA5850SB1AB1B2A1
    Brooks instrument Vietnam 9660 High Temperature Mass Flow Meter
    9660CXF-0004 010C-4RHOVAMMUXXXXCX10EXX
    Brooks instrument Vietnam SLA5850 Thermal Mass Flow Controller
    SLA5850SB1EE1B2A1
    Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
    Mechanical Connections B1 1/4” Tube Compression Fittings W/Filter
    O-ring Material E EPDM for sensor o-ring, Teflon for the rest
    Valve Seat Material E EPDM
    Valve Type 1 Normally Closed
    Analog I/O B 0-5 Vdc
    Power Supply 2 +24 Vdc
    Output Enhancement A Standard Setting / Response Time
     
    8-14kg package included
     
    Note: We cannot quote with 220VAC power supply.
    BUT We can only do +/-15 V or +24 V type.
    Brooks instrument Vietnam Model Code: 2510A2A17SVVT
    Revision A Rev A
    Tube Code 2A17 4-50 LPM air
    Fittings S Stainless Steel
    Valve V Standard Inlet Valve
    Seals VT Viton
    Meter Specifications
    Meter Range                                 : 4– 50 LPM, Air @ 14.7 psia & 70 DegF
    Max Pressure                                : 100 psi-g
    Max Temperature                          : 65 °C     
    Accuracy                                        : 5% FS
    Fitting                                             : 1/8” NPT-F , inlet back, outlet back
    Brooks instrument Vietnam Model Code: 2510A2A18SVVT
    Revision A Rev A
    Tube Code 2A18 10-100 LPM air
    Fittings S Stainless Steel
    Valve V Standard Inlet Valve
    Seals VT Viton
    Meter Specifications
    Meter Range                                 : 10– 100 LPM, Air @ 14.7 psia & 70 DegF
    Max Pressure                                : 100 psi-g
    Max Temperature                          : 65 °C     
    Accuracy                                        : 5% FS
    Fitting                                             : 1/8” NPT-F , inlet back, outlet back
    Brooks Vietnam Brooks Sho-Rate 1355E Series
    Code: 1355EXXXCFX1A 
    (Sho-RateTM "150" Model 1355E
    Code: 1355EB2BCFQ1A)
    BrooksInstrument Vietnam 5850TR Mass Flow Controller
    5850TRGA2C102AA
    Brooks Vietnam GF40 Thermal Mass Flow Controller
    O2 200 sccm
    GF040-C-XX-C-0015 200C-T2-A-V-S5-XXXX-A-X-70F
    Brooks Vietnam GF40 Thermal Mass Flow Controller
    O2 2 slpm
    GF040-C-XX-C-0015 002L-T2-A-V-S5-XXXX-A-X-70F
    Brooks Vietnam GF40 Thermal Mass Flow Controller
    He 2 slpm
    GF040-C-XX-C-0001 002L-T2-A-V-S5-XXXX-A-X-70F
    Brooks Vietnam GF40 Thermal Mass Flow Controller
    C2F6 20 sccm
    GF040-C-XX-C-0118 020C-T2-A-V-S5-XXXX-A-X-70F
    Brooks Vietnam GF80 Thermal Mass Flow Controller
    Cl2 200 sccm
    GF080-C-XX-C-0019 200C-VX-A-M-S5-XXXX-A-X-70F
    Brooks Vietnam BM Series Oval Gear Meter
    Model: BM01ASSPA2BVA
    (Model: BM01BRSPA2BVA)
    Brooks Vietnam BM Series Oval Gear Meter
    Model: BM01BRRPA2BKC
    BM01B: 1/4 inch
    Body / Rotor Material RR: PPS Body & Rotor
    Pulser / Display P: Pulse
    Construction A: Standard Construction
    Process connection 2: 1/4” NPT-F
    Switch Type B: Reed Switch and Hall Effe
    O-rings / Seals K: Teflon
    Options C: Hastelloy C Shafts
    (Model: BM01BRSPA2BVA)
    Brooks Vietnam BM Series Oval Gear Meter
    Model: BM40ASSN4N1CKAA
    BM40A: 1 ½ inch
    Body / Rotor Material SS: 316 SS
    Pulser / Display N: Mechanical Register- Liters
    Process connection 4: Flange ANSI 150lbs RF
    Switch Type N: None-Mechanical Register
    Viscosity 1: Standard < 1000 cP
    Temperature Class C: Standard 316 SS rotors, 120 degC
    Seals K: Teflon
    Options AA: None
    (Model: BM40ASSN4N1CVAA)
    Brooks Vietnam Special note: 
    BM01 flow range is 2-100 L/hr. This is lowest.
    Also the model code you selected is no longer valid. For PPS body, we now only supply in PPS rotor and with Hastelloy C Shaft.
    Do note for BM40 with mechanical register, it only shows totalize flow. It does not show flow rate.
    Brooks Instruments Vietnam Brooks 3809 Armored Flow meter
    3809EZXXXX
    Note: This is special model due to JIS 10k flange hence model code is temporary showing "XXXX".
    (Flow unit: m3/min
    Flow rate: 12-14 m3/min
    Operating pressure: 7 bar
    Size: 3’’
    Connection: JIS 10K)
    Brooks Instrument Vietnam SLA5853 Thermal Mass Flow Controller
    SLA5853S2JAB2C2A1
    SLA5853S: Flow Meter, Body 3
    Digital I/O. Communications: S Smart Emulation (Analog and/or RS485)
    Mechanical Connections: 2J 1-1/2” NPT-F
    O-ring Material A: Viton
    Valve Seat Material B: Viton
    Valve Type 2: Normally Closed (Press Diff > 2 bar)
    Analog I/O C: 4-20 mA
    Power Supply 2: +24 Vdc
    Output Enhancement A: Standard Setting / Response Time
    Certification 1: Standard Location (Safe Area)
    Customer Process
    Fluid                                                    : Air
    Normal Upstream Pressure                : 4 bar-g
    Normal Downstream Pressure            : 1 bar-g
    Meter Specifications
    Meter Flow (Full Scale)                     : 300 Ln/min
    Reference Temp                               : 0 degC
    Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Rating                         : 70 bar-g
    Max Temperature                              : 65 °C
    (Model: SLA5853S/BF 2J A2 B B3 C A1 B1)
    Brooks Instrument Vietnam Recalibration Model 5853S/BE2BA3BB2BA1B1
    For Flow rate between 100-200 slpm N2 Equivalent
    Action : Only recalibration.
    Extra charges if repair required.
    Brooks Instrument Vietnam Recalibration Model 5851S/BD2BA1BB2BA1B1
    Action : Only recalibration.
    Extra charges if repair required
    Brooks Vietnam SLA5853 Thermal Mass Flow Controller
    Model: SLA5853SZXXXX
    Flow Meter, Body 3
    Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
    Mechanical Connections  10mm Tube Compression
    O-ring Material  Viton
    Valve Seat Material  Viton
    Valve Type  Normally Closed (Press Diff > 2 bar)
    Analog I/O  0-5 VDC
    Power Supply  +24 Vdc
    Output Enhancement  Standard Setting / Response Time
    Certification  Standard Location (Safe Area)
    Customer Process
    Fluid                                                    : Air
    Normal Upstream Pressure                : 7 bar-a
    Normal Downstream Pressure            : 1-5 bar-g
    Meter Specifications
    Meter Flow (Full Scale)                     : 400 ln/min
    Reference Temp                               : 0 degC
    Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Rating                         : 70 bar-g
    Max Temperature                              : 65 °C
    Note: Spec reference to T88253/009.
    (Mass flow contronllers and metters
    BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
    SN/Year: T88253/009     2008
    Modelnumber:  5853SBZ1039
    I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
    OP - Press: pa = 7 Bar
    Range/ fluid: 0 - 400 ln/min Air       
    DN 10
    Limit PS 70 barg@TS: 21 độ C  PT 105
                       barg@TS: 21 độ C)
    Brooks Instrument Vietnam Brooks SLA5850 Thermal Mass Flow Controller
    Model Code : SLA5850SB1DD1B2A1
    SLA5850S Flow Controller, Body 0
    Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
    Mechanical Connections B1 1/4” Tube Compression w/Filter
    O-ring Material D Kalrez
    Valve Seat Material D Kalrez
    Valve Type 1 Normally Closed
    Analog I/O B 0-5 VDC
    Power Supply 2 +24 Vdc
    Output Enhancement A Standard Setting / Response Time
    Certification 1 Standard Location (Safe Area)
    (MFC 1: 5850S/BC1GA0AAACA1B1
    Flowrate (30 ml – 3000ml/min)  for wet gas(10% wt SO2 +N2 balance).
    Ope. Pressure max: ? (avoid SO2 condensate to liquid) if condition at Temp: 35°C and the flow: wet gas(10% wt SO2 +N2 balance)
    Output signal: 0..5 Vdc with RS232 interface
    Setpoint signal: 0…5 Vdc or 0..100% RS232
    Connections: 1/4” OD Compression type (male)
    Seals: Kalrez 6375)
    Brooks Vietnam SLA5860 Thermal Mass Flow Meter
    Model Code : SLA5860SB1DA0B2A1
    SLA5860S Flow Meter, Body 0
    Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
    Mechanical Connections B1 1/4” Tube Compression w/Filter
    O-ring Material D Kalrez
    Valve Seat Material A None
    Valve Type 0 None
    Analog I/O B 0-5 VDC
    Power Supply 2 +24 Vdc
    Output Enhancement A Standard Setting / Response Time
    Certification 1 Standard Location (Safe Area)
    Customer Process
    Fluid: 10% SO2, 5% Water vapor, 85% N2 (percentage in mass)
    Normal Upstream Pressure: 60-150 psig
    Normal Downstream Pressure: 0-110 psig
    Operating temperature : 65 degC
    Meter Specifications
    Meter Flow (Full Scale): 3000 mlst/min
    Reference Temp: 70 degF
    Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Rating: 100 bar-g
    Max Temperature: 65 °C
    NOTE: Operating temp cannot exceed 65 degC 
    (MFM 1: 5860S/BC1GA0AACA1B1
    Request: Need to measure correctly (30 ml – 3000ml/min)  for wet gas (10% wt SO2 + 5% steam +N2 balance).
    Flow range: 0…3 ln/min for wet gas(10% wt SO2 + 5% steam +N2 balance)
    Inlet pressure: max. 150 psig @ 70°C
                            max.  60 psig  @ 35°C
    Outlet pressure: 0…110 psig  @ 70°C
                               0 psig @ 35°C
    Temperature: 35°C…70°C
    Output signal: 0..5 Vdc with RS232 interface
    Setpoint signal: 0…5 Vdc or 0..100% RS232
    Connections: 1/4” OD Compression type (male)
    Seals: Kalrez 6375)
    Brooks Instrument Vietnam Brooks SLA5860 Thermal Mass Flow Meter
    Model Code : SLA5860SB1DA0B2A1
    SLA5860S Flow Meter, Body 0
    Digital I/O. Communications S Smart Emulation (Analog and/or RS485)
    Mechanical Connections B1 1/4” Tube Compression w/Filter
    O-ring Material D Kalrez
    Valve Seat Material A None
    Valve Type 0 None
    Analog I/O B 0-5 VDC
    Power Supply 2 +24 Vdc
    Output Enhancement A Standard Setting / Response Time
    Certification 1 Standard Location (Safe Area)
    Customer Process
    Fluid : 10% CH4O (methanol), 10% Water vapor, 30% CO2, 50% H2 (percentage in mass)
    Normal Upstream Pressure                : 1.5-10 bar-g
    Operating temperature                       : 65 degC
    Meter Specifications
    Meter Flow (Full Scale)                     : 1000 mlst/min
    Reference Temp                               : 70 degF
    Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Rating                         : 100 bar-g
    Max Temperature                              : 65 °C
    NOTE: 1) Operating temp cannot exceed 65 degC.
                2) Metal seals not available.
    (MFM 2: 5860S/BC1GA0AACA1B1
    Flow: 20…1000 ml/min for wet gas (10% wt MeOH vapour  +10% steam +30%CO2 50%H2).
    Inlet pressure:. 1.5 barg….10 barg
    Temperature: 35°C…80°C
    Output signal: 0..5 Vdc with RS232 interface
    Setpoint signal: 0…5 Vdc or 0..100% RS232
    Connections: 1/4” OD Compression type (male)
    Seals: Metal)
    Brooks Vietnam SLA5853 Thermal Mass Flow Controller
    Model: SLA5853SZXXXX
    Flow Meter, Body 3
    Digital I/O. Communications  Smart Emulation (Analog and/or RS485)
    Mechanical Connections  10mm Tube Compression
    O-ring Material  Viton
    Valve Seat Material  Viton
    Valve Type  Normally Closed (Press Diff > 2 bar)
    Analog I/O  0-5 VDC
    Power Supply  +24 Vdc
    Output Enhancement  Standard Setting / Response Time
    Certification  Standard Location (Safe Area)
    Customer Process
    Fluid                                                    : Air
    Normal Upstream Pressure                : 7 bar-a
    Normal Downstream Pressure            : 1-5 bar-g
    Meter Specifications
    Meter Flow (Full Scale)                     : 400 ln/min
    Reference Temp                               : 0 degC
    Accuracy                                            : +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Rating                         : 70 bar-g
    Max Temperature                              : 65 °C
    Note: Spec reference to T88253/009.
    (Mass flow contronllers and metters
    BROOKS INSTRUMENT 6718WX - THE NETHERLANDS
    SN/Year: T88253/009     2008
    Modelnumber:  5853SBZ1039
    I/O Signal: 0 - 5VDC 0 - 5VDC & 0 - 20 mA
    OP - Press: pa = 7 Bar
    Range/ fluid: 0 - 400 ln/min Air       
    DN 10
    Limit PS 70 barg@TS: 21 độ C  PT 105
                       barg@TS: 21 độ C)
    Brooks Instrument Vietnam Brooks Model 2500 Series Flowmeters
    Code: 2530A4A68SNVT
    2530 Acrylic Flowmeter
    Revision A: Revision A
    Tube Tube 4A68: 2-20 SCFM Air
    Fittings S: Stainless Steel
    Valve N: No Valve
    Seals VT: Viton
    Brooks Vietnam Brooks Oval Flowmeters
    Replaced by: BM04
    Code: BM04ASSF2H1CKAA
    (Brooks Oval Flowmeters, BM Oval Series, Models BM04 Through BM50 ®
    Code: BM04ASSN2N1ARAA)
    Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
    Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
    Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
    Mechanical Connections 3A: DIN DN15 PN40
    O-ring Material B: Buna
    Valve Seat Material A: None (Meter)
    Valve Type 0: None
    Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
    Power Supply 2: +24 Vdc
    Output Enhancement A: Standard Setting / Response Time
    Certification 1: Standard Location (Safe Area)
    Valve Orifice Size: A No Orifice
    Mass Flow Restrictor Type 5: LFE
    Flow Restrictor Size D: Size D
    Calibration conditions 1: Single S-series calibration
    OEM Code A: Standard Brooks Label
    Software Revision A: Revision A
    Mounting Attitute 1: Horizontal base down
    Baudrate F: 19200
    Customer Process:
    Fluid: CO2
    Normal Upstream Pressure: 18 bar-g
    Meter Specifications:
    Meter Flow (Full Scale): 40 kg/hr
    Reference Temp : 21.1 degC
    Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Ratin: 70 bar-g
    Max Temperature: 65 °C
    Ingress Protection: IP66
    SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
    Note: IP 66 tot hon IP65
    (SLA5863S3ABA0C2A1A5D1AA
    IP65)
    Brooks Instrument Vietnam Model Code: SLA5853S2CAB2B2A1 
    SLA5853 Mass Flow Controller
    Digital I/O, Communication S: Smart Emulation (analog or RS-485)
    Mechanical Connection 2C: 3/8” Compression
    O-ring material A: Viton
    Valve Seat material B: Viton
    Valve Type 2: Normally Close
    Analog I/O B: 0-5 Volt
    Power Supply 2: +24 Vdc
    Output Enhancement A: Standard Setting / Response time
    Certification 1: Standard Location
    * Customer Process Data:
    Fluid: Air
    Upstream Pressure: 5-10 kg/cm2-g
    Downstream Pressure:  Customer to advice
    * Meter Specifications:
    Meter Range (Full Scale): 500 slpm
    Ref Temperature: 70 degF
    Accuracy: +/- 1% Rate
    Max Pressure Rating: 100 bar g
    Max Temperature: 65 °C
    NOTE: Please confirm whether it is ln/min, lst/min or la/min that you need. 
    (Brooks Instrument mass flow controller for nitrogen and air.
    - Flow rate: 0 - 500 lit/minute
    - Compress air about 5 - 10 kg/cm2
    - I/O digital signal can controlled by computer.
    - Material for flow meter is metal)
    Brooks Vietnam SLAMF63 Thermal Mass Flow Meter
    Replaced by: SLAMF63S3ABA0G2A1A5D1AA1F
    Digital I/O. Communications S: Smart Emulation (Analog and/or RS485)
    Mechanical Connections 3A: DIN DN15 PN40
    O-ring Material B: Buna
    Valve Seat Material A: None (Meter)
    Valve Type 0: None
    Analog I/O G: 4-20mA I/O (PG11 Cable Gland)
    Power Supply 2: +24 Vdc
    Output Enhancement A: Standard Setting / Response Time
    Certification 1: Standard Location (Safe Area)
    Valve Orifice Size: A No Orifice
    Mass Flow Restrictor Type 5: LFE
    Flow Restrictor Size D: Size D
    Calibration conditions 1: Single S-series calibration
    OEM Code A: Standard Brooks Label
    Software Revision A: Revision A
    Mounting Attitute 1: Horizontal base down
    Baudrate F: 19200
    Customer Process:
    Fluid: CO2
    Normal Upstream Pressure: 18 bar-g
    Meter Specifications:
    Meter Flow (Full Scale): 40 kg/hr
    Reference Temp : 21.1 degC
    Accuracy: +/- 1% Rate (20% to 100% FS), +/-0.2% FS (Below 20% FS)
    Max Pressure Ratin: 70 bar-g
    Max Temperature: 65 °C
    Ingress Protection: IP66
    SLAMF63S3ABA0G2A1A5D1AA1F voi IP 66
    Note: IP 66 tot hon IP65
    (SLA5863S3ABA0C2A1A5D1AA
    IP65)
    Brooks Vietnam 0254 Read Out & Control
    Code: 0254AA2B23A
    Type Housing: Panel Mount Kit
    Power Cord For Power Supply: European Power Cord For 220 VAC
    Power Supply Output Voltage: + 24 VDC
    Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
    Options: RS-232 cable, 3 meter, 9 pin Female “D”
    OEM Code: Standard Brooks Labelling
    Brooks Vietnam 0254 Read Out & Control
    Code: 0254AA2B23A
    Type Housing: Panel Mount Kit
    Power Cord For Power Supply: European Power Cord For 220 VAC
    Power Supply Output Voltage: + 24 VDC
    Input/Output Pinout and Signal Adapters: Current Pinout / Voltage Pinout Adapter Set
    Options: RS-232 cable, 3 meter, 9 pin Female “D”
    OEM Code: Standard Brooks Labelling
    Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
    Model: SLA5863S3ABA0C2A1A5D1AA
    (Model: SLA5863S3A0C2A1A5D1AA
    SN : F13319-001
    Gas : CO2
    Flow rate : 0-40kg/h)
    Brooks Instrument Vietnam Brooks SLA5863 Thermal Mass Flow Meter
    Model: SLA5863S3ABA0C2A1A5D1AA
    (Model: SLA5863S3A0C2A1A5D1AA
    SN : F13319-001
    Gas : CO2
    Flow rate : 0-40kg/h)
    Brooks Instrument Vietnam Replaced by: 1250A-D6041
    Brooks Instrument Flowmeter
    1250 Glass Tube Flow meter
    1250A: Glass Tube Flow Meter With Horizontal Connections
    Tube model: D6041 Glass float
    Fluid Type:  Air
    Unit of measurement:   CCM
    End Block Material:  Stainless Steel
    Valve Designation:  Needle Valve at inlet
    O-ring material:  Viton
    Fitting: 1/4" NPT-F
    Note: 1510 model is discontinued. Replacement model is 1250. But flow range is not exactly same. I quoted 20-900 ccm Air. Next higher is 50-1200 ccm
    (Model: 1510 with meet the below specifications
    Pressure: 300psig up to 250oF max
    Material : Glass 316SS
    Connections: 1/4"NPT
    Type of Fluid: Gas.
    Flow range: 100-1000ccm
    Line valve inlet)
    Brooks Vietnam 3809 Armored Flowmeter
    3809/E12D1BEAEAA
    Note: 
    ·         We are assuming it is water for now.
    Do find out the liquid density and viscosity and the flow range required.
    ·         This model we quoted comes with 4-20mA output transmitter. 
    ·         We follow the code your sales engineer provided.
    ·         If signal output is not required, please confirm then price is much lower. 
    (Model: 3809E12D1)
    Brooks Instrument Vietnam 5850E Mass Flow Controller
    Brooks Instrument
    Model: 5850EC1BF3PB2A
    S/N: 8611HCO23461/1.
    Chia sẻ:
    Bài viết khác:
    Zalo
    Hotline